Der Artikel ist weiterhin als ^^OTHERCONDITION^^ verfügbar.
Autor: Robert Smolenski
ISBN-13: 9781447160199
Einband: Previously published in hardcover
Seiten: 184
Gewicht: 287 g
Format: 235x155x10 mm
Sprache: Englisch

Conducted Electromagnetic Interference (EMI) in Smart Grids

 Previously published in hardcover
Sofort lieferbar | Versandkosten
Geben Sie Ihre Bewertung ab!  
Wir verlosen jeden Monat unter allen freigegebenen Rezensionen
3 Gutscheine im Wert von 20 Euro. Teilnahmebedingungen
Robert Smolenski was born in 1973 in Krosno Odrzanskie, Poland. He was awarded M.Sc. and Ph.D. degrees in electrical engineering from the University of Zielona Gora. He is currently a researcher and Deputy Head of the Institute of Electrical Engineering at the University of Zielona Gora. Dr Robert Smolenski has over ten years of experience in development of practical solutions to EMC related problems and has been involved in realization of many national and international research projects. Author of numerous papers in the field of EMC and reviewer for prestigious journals. At present the member of IEEE Electromagnetic Compatibility Society, taking a part in the activities of SC1 Special Commission on Smart Grid, member of Polish Society for Theoretical and Applied Electrical Engineering.
As more renewable energy sources come on line, power distribution systems may be disrupted by the changes involved. This volume examines the electromagnetic interference accompanying the implementation of the 'smart grids' needed for greener electricity.
Presents specific conducted EMI related phenomena accompanying the application of Smart Grids techniques as well as the recommendation of the effective methods enabling assurance of system compatibility and reliability
Includes EMC analyses which are important from Smart Grid systems reliability point of view and are not covered by international EMC standards
Shows analyses and results of measurements of EMI generated by individual power electronic converters, commonly applied in Smart Grids, experimental evaluation of an interference penetration depth into LV and MV lines, experimental results and mathematical approach to aggregated EMI, generated by group of the power electronic converters, influence of the EMI generated by power electronic converters on the control signals transmission, limitation of the EMC standards in a context of Smart Grid compliance evaluation
Introduction.- 1. Power Electronic Interfaces in Smart Grids.- 2. Standardized measurements of conducted EMI.- 3. Conducted EMI issues in Smart Grids.- 4. Shaping of the EMI characteristics in Smart Grids.- 5. Compensation of interference sources inside Power Electronic Interfaces.- 6. EMI measuring procedures in Smart Grids.- 7. Conclusion.- Appendix A. Essential parameters.- Index.
As power systems develop to incorporate renewable energy sources, the delivery systems may be disrupted by the changes involved. The grid's technology and management must be developed to form Smart Grids between consumers, suppliers and producers. Conducted Electromagnetic Interference (EMI) in Smart Grids considers the specific side effects related to electromagnetic interference (EMI) generated by the application of these Smart Grids.Conducted Electromagnetic Interference (EMI) in Smart Grids presents specific EMI conducted phenomena as well as effective methods to filter and handle them once identified. After introduction to Smart Grids, the following sections cover dedicated methods for EMI reduction and potential avenues for future development including chapters dedicated to:

-potential system services,
-descriptions of the EMI spectra shaping methods,
-methods of interference voltage compensation, and theoretical analysis of experimental results.

By focusing on these key aspects, Conducted Electromagnetic Interference (EMI) in Smart Grids provides a concise and comprehensive coverage of an extensive subject matter. It constitutes a key resource for any industry practitioners, researchers or system designers with interest in Smart Grids, particularly their electromagnetic compatibility in the conducted EMI frequency range.
Autor: Robert Smolenski
Robert Smolenski was born in 1973 in Krosno Odrzanskie, Poland. He was awarded M.Sc. and Ph.D. degrees in electrical engineering from the University of Zielona Gora. He is currently a researcher and Deputy Head of the Institute of Electrical Engineering at the University of Zielona Gora. Dr Robert Smolenski has over ten years of experience in development of practical solutions to EMC related problems and has been involved in realization of many national and international research projects. Author of numerous papers in the field of EMC and reviewer for prestigious journals. At present the member of IEEE Electromagnetic Compatibility Society, taking a part in the activities of SC1 Special Commission on Smart Grid, member of Polish Society for Theoretical and Applied Electrical Engineering.

Zu diesem Artikel ist noch keine Rezension vorhanden.
Helfen sie anderen Besuchern und verfassen Sie selbst eine Rezension.

 

Rezensionen

Autor: Robert Smolenski
ISBN-13 :: 9781447160199
ISBN: 1447160193
Erscheinungsjahr: 13.04.2014
Verlag: Springer London
Gewicht: 287g
Seiten: 184
Sprache: Englisch
Auflage 2012
Sonstiges: Taschenbuch, 235x155x10 mm